About admin

This author has not yet filled in any details.
So far admin has created 109 blog entries.

The Wire-form Fixation Device: A New Device for the Fixation of Medial Malleolar Fractures

2021-08-12T18:45:43-07:00

Rutter M, Richard R, Irgrit K, Cush G Techniques in Foot & Ankle Surgery, 14(2), 94–98, June 2015  Background: To examine outcomes of open reduction internal fixation (ORIF) of patients with medial malleolar fractures that were fixed using a wire-form fixation device. We hypothesize that patients who undergo operative intervention using

The Wire-form Fixation Device: A New Device for the Fixation of Medial Malleolar Fractures2021-08-12T18:45:43-07:00

Distal fibula fracture fixation Biomechanical evaluation of three different fixation implants

2021-08-12T18:34:11-07:00

Knutsen, A, MS, Sangiorgio, S N, PhD, Lui, C, Zhou, S, BS, Warganich, T, MD, Fleming, J, MD, Harris, T, MD, Ebramzadeh, E, PhD Foot and Ankle Surgery, 22(4), 278-285., December 2016 Background: The goal of this study was to evaluate the biomechanical performance of three distal fibula fracture fixation implants

Distal fibula fracture fixation Biomechanical evaluation of three different fixation implants2021-08-12T18:34:11-07:00

Distal Sled Fixation for Horizontal Medial Malleolus Fractures

2020-08-21T00:09:27-07:00

Wegner AM, MD, PhD, Wolinsky PR, MD, Cheng RZ, B.S., Robbins MA, BS, Garcia TC, MS, Amanatullah DF, MD, PhD Clinical Biomechanics, 42, 92-96, February 2017 Background: Horizontal fractures of the medial malleolus occur through various rotational forces of the ankle, including supination-external rotation, pronation-external rotation, and pronation abductionc. Many methods

Distal Sled Fixation for Horizontal Medial Malleolus Fractures2020-08-21T00:09:27-07:00

An Anatomic and Kinematic Analysis of a New Total Wrist Arthoplasty Design

2021-08-12T18:33:57-07:00

Hooke A W MA, Petterson K MD, Sagefors M. MD, An K MD, Rizzo M MD Journal of Wrist Surgery, 04(02), 121–127.  Background: Total wrist arthroplasty (TWA) is a viable surgical treatment for disabling wrist arthritis. While current design are a notable improvement from prior generations, radiographic loosening and failures remain a

An Anatomic and Kinematic Analysis of a New Total Wrist Arthoplasty Design2021-08-12T18:33:57-07:00

Biomechanical comparison of the holding strenght of a Peek Optima Circular Plate vs a Stainless Steel Oblique T-Plate for Radioscapholunate Arthrodesis

2021-08-12T18:32:36-07:00

Isaacs, J., M.D., Yen Shipley, N., M.D., Owen, J., M.D., Patterson Owings, F., B.A., Wayne, J., PhD. The Journal of Hand Surgery, 33(10), 1765-1769, December 2008 Purpose: Radioscapholuate arthrodesis is an accepted treatment for posttraumatic radiocarpal arthritis that preserves some wrist motion. Good results are dependent on secure fixation while avoiding

Biomechanical comparison of the holding strenght of a Peek Optima Circular Plate vs a Stainless Steel Oblique T-Plate for Radioscapholunate Arthrodesis2021-08-12T18:32:36-07:00

Biomechanical comparison of three fixation techniques used for four-corner arthrodesis

2021-08-12T18:44:44-07:00

J. Kraisarin, MD; D.G. Dennison, MD; L.J. Berglund, BS; K.N. An, PhD and Alex Y. Shin, MD  Journal of Hand Surgery (European Volume), 36(7), 560-567. Sept 7, 2011 Abstract: Clinical results following four-corner arthrodesis vary and suggest that nonunion may be related to certain fixation techniques. The purpose of our study

Biomechanical comparison of three fixation techniques used for four-corner arthrodesis2021-08-12T18:44:44-07:00

The rate of successful four-corner arthrodesis with a locking, dorsal circular polyether-ether-ketone (PEEK-Optima) plate

2021-08-12T18:41:25-07:00

Rhee PC, Shin AY Journal of Hand Surgery (European Volume), 38(7), 767-773. Feb 6, 2013 Abstract: The purpose of this study is to evaluate the rate of union after four-corner arthrodesis with a locking, dorsal circular plate comprised of polyether-ether-ketone. A retrospective review was conducted of all patients who underwent four-corner

The rate of successful four-corner arthrodesis with a locking, dorsal circular polyether-ether-ketone (PEEK-Optima) plate2021-08-12T18:41:25-07:00

Four-Corner Arthrodesis with a Radiolucent Locking Dorsal Circular Plate

2021-05-28T15:20:26-07:00

Rudnick B, Goljan P, Pruzansky J, Bachoura A, Jacoby S, Rekant M Technique and Outcomes. Hand, 9(3), 315-321, September 2014 Abstract: Background: Scaphoid excision and four-corner arthrodesis (FCA) is an acceptable motion sparing procedure used to treat wrist arthritis. Recently, a locking dorsal circular plate composed of polyether-ether-ketone has been introduced (Xpode, TriMed,

Four-Corner Arthrodesis with a Radiolucent Locking Dorsal Circular Plate2021-05-28T15:20:26-07:00

The Ulnar Shortening Osteotomy

2020-07-31T21:42:13-07:00

Anthony J. Lauder, M.D., Douglas P. Hanel, M.D., Thomas E. Trumble, M.D. American Society for Surgery of the Hand, Chapter 18, Copyright ASSH 2006

The Ulnar Shortening Osteotomy2020-07-31T21:42:13-07:00
Go to Top